Hello, Try to use ACK_GL instruction in your safety program. This block re-integrates all passivated I/O modules. If after acknowledgement the problem still exist, please check the wiring of the two channels. Try also to increase the descrepancy time. Good luck.
Hello,
Try to use ACK_GL instruction in your safety program. This block re-integrates all passivated I/O modules.
If after acknowledgement the problem still exist, please check the wiring of the two channels.
Try also to increase the descrepancy time.
Good luck.
How to fix Safety program F-IO channel passivated error?
Hello, Try to use ACK_GL instruction in your safety program. This block re-integrates all passivated I/O modules. If after acknowledgement the problem still exist, please check the wiring of the two channels. Try also to increase the descrepancy time. Good luck.
Hello,
Try to use ACK_GL instruction in your safety program. This block re-integrates all passivated I/O modules.
See lessIf after acknowledgement the problem still exist, please check the wiring of the two channels.
Try also to increase the descrepancy time.
Good luck.